产品详情
文献和实验
相关推荐
库存 :500支
供应商 :研卉生物
现货状态 :有
规格 :50支/盒
Pall针头滤器4612/4614PALL(颇尔)针头过滤器
4612 0.2um, 25mm, 50个/包 独立包装
4614 0.45um, 25mm, 50个/包 独立包装
Superior flow rates and higher throughputs than competitive devices.
Low protein binding to minimize sample loss.
Pre-sterilized products are sterilized by gamma irradiation to eliminate potential contamination by EtO residuals.
A range of sizes (13 to 37 mm) accommodates sample volumes from < 10 to 150 mL.
Acrodisc PF and Serum Acrodisc syringe filters feature built-in prefilter for increased throughput of difficult-to-filter liquids.
Reduces mycoplasma with the use of 0.1 μm pore size.
0.1 and 0.2 μm pore sizes provide sterilization of small volumes of buffers, culture media, and additives.
Acrodisc PF and Serum Acrodisc syringe filters are ideal for clarification/sterilization of viscous or particulate-laden solutions.
Use larger pore size filters for prefiltration and particulate removal.
Materials of Construction
Filter Media: Supor membrane [hydrophilic polyethersulfone (PES)]Serum Acrodisc Prefilter Media: Binder-free borosilicate glass
Acrodisc Housing:
13 mm: Polypropylene
25 and 32 mm: Modified acrylic
37 mm: Polypropylene
Serum Acrodisc Housing: ABS
Pore Size
0.1, 0.2, 0.45, 0.8, 1.2, and 5 µm
Effective Filtration Area
13 mm: 1.0 cm225 mm: 2.8 cm2
32 mm: 5.8 cm2
37 mm: 7.5 cm2
Inlet/Outlet Connections
Female luer lock inlet, male slip luer outlet
Typical Hold-Up Volume
(with air purge)13 mm: < 28 µL
25 mm: < 70 µL
32 and 37 mm: <100 µL
Maximum Operating Temperature
55 °C (131 °F)
Maximum Operating Pressure
5.2 bar (520 kPa, 75 psi)
Typical Water Flow Rate
mL/min at 3.1 bar (310 kPa, 45 psi)0.1 μm, 25 mm: 35
0.1 μm, 32 mm: 100
0.2 μm, 13 mm: 22
0.2 μm, 25 mm: 175
0.2 μm, 32 mm: 490
0.45 μm, 13 mm: 35
0.45 μm, 25 mm: 300
0.45 μm, 32 mm: 700
0.8 μm, 13 mm: 150
0.8 μm, 25 mm: 700
0.8/0.2 μm, 25 mm: 145
0.8/0.2 μm, 32 mm: 440
1.2 μm, 32 mm: 1700
5 μm, 32 mm: 1750
GF/0.2 μm, 37 mm (Serum
Acrodisc Filter): 425
Endotoxin Level
< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test
Biological Safety
Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>
Sterilization
Sterilized by gamma irradiation and individually blister packaged. All bulk packages provided non-sterile including PN 4504, 4506, 4508, 4509, 4655, 4653, 4659, 4660, 4661, 4662, 4668, and 4692.Built-In Prefilter Enhances Throughput of Viscous, Particulate-Laden, or Proteinaceous Solutions
Acrodisc Syringe Filters with Supor Membrane, Sterile | ||||
---|---|---|---|---|
4602 | 0.2 µm, 13 mm | 75/pkg | ||
4604 | 0.45 µm, 13 mm | 75/pkg | ||
4608 | 0.8 µm, 13 mm | 75/pkg | ||
4611 | 0.1 µm, 25 mm | 50/pkg | ||
4612 | 0.2 µm, 25 mm | 50/pkg | ||
4614 | 0.45 µm, 25 mm | 50/pkg | ||
4618 | 0.8 µm, 25 mm | 50/pkg | ||
4651 | 0.1 µm, 32 mm | 50/pkg | ||
4652 | 0.2 µm, 32 mm | 50/pkg | ||
4654 | 0.45 µm, 32 mm | 50/pkg | ||
4656 | 1.2 µm, 32 mm | 50/pkg | ||
4650 | 5 µm, 32 mm | 50/pkg |