大鼠/小鼠脑缺血MCAO模型尼龙栓线(线栓)

大鼠/小鼠脑缺血MCAO模型尼龙栓线(线栓)

价格: 询价

品牌:Doccol

货号:40SP

收藏

产品详情

相关推荐

大鼠/小鼠脑缺血MCAO模型尼龙栓线(线栓)
[ 作者:佚名 | 来源:本站原创 | 点击数:3310 | 更新时间:2009-11-03 ]
大鼠/小鼠脑缺血MCAO模型尼龙栓线(线栓)
Doccol Made a Difference in Stroke Modeling

Doccol MCAO Sutures Reduce SD to 5% of Its Corresponding Mean Value for Infarction Volume

In the stroke model literature, two types of MCAO models are most frequently used, which are the Koizumi model (Koizumi et al. 1986), and the Longa model (Longa et al. 1989). The Koizumi model suggested the use of silicon rubber-coated monofilaments as occludors whilst the Longa model used flame-blunted monofilaments. It turned out that silicon rubber-coated monofilaments are superior to flame-blunted monofilaments for producing consistent ischemic brain injuries. A study (Tsuchiya et al. 2003) showed that using flame-blunted monofilaments for inducing MCA occlusion caused 40% occurrence of subarachnoid hemorrhage, and the standard deviation for infarction volume was greater than its corresponding mean value. Another technical paper specifically compared the effects of suture types on the infarct consistency and showed that silicon rubber-coated monofilaments were superior to flame-blunted ones, producing consistent infarction; and this was true even with inexperienced surgeons. (Shimamura et al. 2006a) In the mouse intraluminal model, SAH rate could reach 40% if uncoated heat-blunted monofilaments being used; and such a modeling method resulted in the deviation for infarction volume being larger than 50% of its corresponding mean value. (Tsuchiya et al. 2003) The poly-L-Lysine coated monofilament seemed could only increase the mortality (to a rate of 60%), without any benefits for reducing infarct variation. (Huang et al. 1998)

规格标准(大鼠不同体重用不同规格的栓线)
价格,


Animal Body Weight (g) Suggested Diameters (mm) Filament USP “0” # Available Coating Lengths (mm) Using Search Function My Special Design subcategories
15-20 0.17,0.19 70 2-10 Search “70”, “7017”, “7019” “70SPRe”
20-25 0.21, 0.22 70, 60 2-10 Search “70”, “60” “70SPRe”, “60SP”, and “60SPRe”
25-30 0.22, 0.23 70, 60 2-10 Search “70”, “60” “70SPRe”, “60SP”, and “60SPRe”
30-35 0.23 60 2-10 Search “60” “60SP”, and “60SPRe”
<200 0.31, 0.33, 0.29 50 2-6* Search “50” “50SPRe”
<200-250 0.33, 0.35 50, 40 2-6* Search “50”, “40”; “5033”, “4035” “50SPRe”, “40SP”, and “40SPRe”
250-280 0.35, 0.37 40 2-6* Search “40”; “4035”, “4037” “40SP”, and “40SPRe”
280-330 0.37, 0.39 40 2-6* Search “40”; “4037”, “4039” “40SP”, and “40SPRe”
330-400 0.41 40, 30 2-6 Search “40”, “30” “40SP”, “40SPRe”, and “30SP”
>400 0.43 30 2-6 Search “30” “30SP”



美国健康医疗仪器国际公司

实名认证

金牌会员

入驻年限:11年

联系人:付老师

地址:成都

电话联系

立即询价

换一个