NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0

NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0

价格: 询价

品牌:瑞孚迪 Revvity 品牌认证

货号:NOVA-5198-01

收藏

产品详情

相关推荐

库存 :8 Rxn、48 Rxn、96 Rxn

英文名 :NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0

供应商 :蓝景科信

New & Improved Library Preparation Kit for your RNA Sequencing Needs

The NEXTFLEX® rapid directional RNA-seq kit 2.0 produces libraries for Illumina® sequencing instruments with high coverage uniformity, low duplication rates, strand specificity and minimal rRNA contamination when used with the NEXTFLEX® Poly(A) Beads 2.0 (10 ng – 5 μg) or NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat) (5 ng – 1 μg). This kit includes reverse transcriptase, necessary library preparation reagents, and cleanup/size selection beads optimized to ensure reliable performance. The kit involves a simple library preparation protocol that has been validated with the updated NEXTFLEX® poly(A) beads 2.0 and NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat) to accommodate total RNA as input. The NEXTFLEX® rapid directional RNA-seq kit 2.0 is designed to be used with NEXTFLEX® RNA-Seq 2.0 Unique Dual Index Barcodes (6.25μM), which are color-balanced and have undergone proprietary purity QC metrics to generate reliable sequencing results for every sample.

 

产品特点:

  • Reliable: High coverage uniformity with low duplication rate
  • Convenient: Optimized for use with 5 ng – 5 µg total RNA with reverse transcriptase and cleanup/size selection beads included
  • Streamlined: Simple protocol validated with NEXTFLEX® poly(A) beads 2.0  and NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat)
  • Flexible: Designed to work with NEXTFLEX® RNA-Seq 2.0 Unique Dual Index barcodes that allow a wide range of multiplexing (2 up to 1,526 samples in one run)
  • Efficient: Automated on the Sciclone® G3 NGSx and Zephyr® G3 NGS workstations

 

产品列表:

货号 产品名称 规格
NOVA-5198-01

NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0

8 RXNS
NOVA-5198-02

NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0

48 RXNS
NOVA-5198-03

NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0

96 RXNS



image.png
 

PERFORMANCE OF POLY(A)-SELECTED LIBRARIES

image.png

Figure 1. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrates even coverage along transcripts compared to the Competitor N kit. Poly(A) mRNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX® Poly(A) beads 2.0 and the Competitor N Poly(A) enrichment kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using paired-end mode (2×76 bp). Reads were trimmed using cutadapt and mapped to the Gencode v30 reference using bowtie2. The coverage along transcripts was calculated using the BBMap pileup tool.

image.png

Figure 2. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrate low duplication rate compared to the Competitor N kit. Poly(A) mRNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX® Poly(A) beads 2.0 and the Competitor N Poly(A) enrichment kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using paired-end mode (2×76 bp). Reads were trimmed using cutadapt, mapped to the Gencode v30 reference using bowtie2, and randomly downsampled to 100k reads. Duplication rate was calculated using the fastp all-in-one FASTQ preprocessor.

image.png

Figure 3. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrates comparable directionality to the Competitor N kit. Poly(A) mRNA was isolated from Universal Human Reference RNA (Agilent #740000) containing ERCC RNA Spike-In mix (Thermo Fisher Scientific #4456740) using the NEXTFLEX® Poly(A) Beads 2.0 and the Competitor N Poly(A) enrichment kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using paired-end mode (2×76 bp). Reads were trimmed using cutadapt and mapped to the ERCC92 reference using bowtie2. Strandedness was calculated using SAMtools.

image.png

Figure 4. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 delivers libraries containing low levels of rRNA contamination than the Competitor N kit. Poly(A) mRNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX® Poly(A) Beads 2.0 and the Competitor N Poly(A) enrichment kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using paired-end mode (2×76 bp). The reads were trimmed using cutadapt and the percent of rRNA was determined by using bowtie2 to map reads to human rRNA. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrated superior removal of 5S, 5.8S, 12S, 16S, 18S, and 28S rRNA species compared to the Competitor N kit.

image.png

Figure 5. Libraries prepared using the Zephyr® G3 NGS workstation and manually deliver comparable yields using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0. Poly(A) mRNA was isolated from Universal Human Reference RNA (Agilent® #740000) using the NEXTFLEX® Poly(A) Beads 2.0. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0. Final library concentrations were quantified using the Qubit® 2.0 fluorometer (Thermo Fisher® Scientific #Q32866).

 

PERFORMANCE OF rRNA-DEPLETED LIBRARIES

 

image.png

Figure 1. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrates even coverage along transcripts compared to the Competitor N kit. Poly(A) mRNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX® Poly(A) beads 2.0 and the Competitor N Poly(A) enrichment kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using paired-end mode (2×76 bp). Reads were trimmed using cutadapt and mapped to the Gencode v30 reference using bowtie2. The coverage along transcripts was calculated using the BBMap pileup tool.

image.png

Figure 2. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrate low duplication rates compared to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent® #740000) using the NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using single-end mode (1×151 bp). Reads were trimmed using cutadapt, mapped to the Gencode v30 reference transcriptome using bowtie2, and randomly downsampled to 28k reads. Duplication rate was calculated using the fastp all-in-one FASTQ preprocessor.

image.png

Figure 3. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrates comparable directionality relative to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent® #740000) using the NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using single-end mode (1×151 bp). Reads were trimmed using cutadapt and mapped to the Gencode v30 reference transcriptome using bowtie2. Reads from respective samples were combined and downsampled for a total of 800k reads each. Strandedness was calculated using the fastp all-in-one FASTQ preprocessor.

image.png

Figure 4. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 delivers libraries containing low levels of rRNA contamination compared to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina® MiSeq® sequencer using single-end mode (1×151 bp). The reads were trimmed using cutadapt and the percent of rRNA was determined by using bowtie2 to map reads to human rRNA. The NEXTFLEX® Rapid Directional RNA-Seq kit 2.0 demonstrated superior removal of 5S, 5.8S, 12S, 16S, 18S, and 28S rRNA species compared to the Competitor N kit.

image.png

Figure 5. Libraries prepared using the Sciclone® G3 NGSx workstation and manually deliver comparable yields using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX® RiboNaut™ rRNA depletion kit. Libraries were generated using the NEXTFLEX® Rapid Directional RNA-Seq kit 2.0. Final library concentrations were quantified using the Qubit® 2.0 fluorometer (Thermo Fisher Scientific #Q32866).
 

KIT CONTENTS

  • NEXTFLEX® RNA-Seq Fragmentation Buffer 2.0
  • NEXTFLEX® Directional First Strand Synthesis Buffer Mix 2.0
  • NEXTFLEX® Rapid Reverse Transcriptase 2.0
  • NEXTFLEX® Directional Second Strand Synthesis Mix 2.0
  • NEXTFLEX® RNA-Seq Adenylation Buffer Mix 2.0
  • NEXTFLEX® RNA-Seq Adenylation Enzyme 2.0
  • NEXTFLEX® RNA-Seq Ligase Buffer Mix 2.0
  • NEXTFLEX® RNA-Seq Ligase Enzyme 2.0
  • NEXTFLEX® RNA-Seq PCR Master Mix 2.0
  • NEXTFLEX® RNA-Seq Primer Mix 2.0 (50 µM)
  • Nuclease-free Water
  • Resuspension Buffer
  • NEXTFLEX® Cleanup Beads XP

 

REQUIRED  MATERIALS NOT PROVIDED

  • 10 ng – 1 µg total RNA for enrichment by NEXTFLEX® Poly(A) Beads or ~ 1 ng – 100 ng isolated mRNA or 5 ng – 1 µg rRNA-depleted total RNA using NEXTFLEX® RiboNaut™ rRNA depletion kit (human, mouse, rat) or 1 ng – 100 ng of isolated mRNA or rRNA-depleted RNA using alternative methods
  • DynaMag™-2 Magnet (Thermo Fisher Scientific, Cat # 123-21D)
  • 100% Ethanol (stored at room temperature)
  • 2, 10, 20, 200 and 1000 µL pipettes
  • RNase-free pipette tips
  • Nuclease-free 1.5 mL microcentrifuge tubes
  • Thin wall nuclease-free 0.5 mL microcentrifuge tubes
  • 96 well PCR Plate Non-skirted (Phenix Research, Cat # MPS-499) / or / similar
  • Adhesive PCR Plate Seal (Bio-Rad, Cat # MSB1001)
  • Magnetic Stand -96 (Thermo Fisher Scientific, Cat # AM10027) / or / similar for post PCR cleanup
  • Microcentrifuge
  • Thermal cycler
  • Heat block
  • Vortex

蓝景科信河北生物科技有限公司

代理商

实名认证

钻石会员

入驻年限:2年

联系人:刘樊

地址:保定

电话联系

立即询价

换一个